Multi-functional Personal Environmental Monitor
Key Features
- Up to 4 gas sensors, or 1 gas sensor and particulate sensor.
- Monitor PM 1.0, 2.5, 4.0 and 10 simultaneously.
- Noise Dose / Level, Temperature & Humidity Monitoring.
- Barometric pressure.
- GPS Location option.
- Download data to PC for record retention and reporting.
- Bluetooth™ connectivity.
- Cloud data analytics option.
- Black or Orange (hi-viz) silicon grip.
- Small and light for easy monitoring.
- Visual / Audible Warning of hazards.
- Klick Fast connector for use with a range of attachments.
- Battery life up to 160hrs (4 working weeks).
- Rechargeable using USB-C.
Product Gallery
Klick Fast Dock Options
There is a Klick Fast dock available for any situation and once located on a strap, belt, item of clothing or even bicycle handlebars it can be used to securely hold any device or case fitted with the Klick Fast connector. Below are some of the available docks with more available at Peter Jones (ILG) Ltd.






See more Klick Fast Dock options on the Peter Jones (ILG) Ltd website.
PEM Cost Calulator
As a UK customer you can use our PEM Cost Calculator to work out the cost of a PED 1780 with different combinations of sensors.
You have the option for a Particulate Matter Sensor and choice of one Gas Sensor or up to four Gas Sensors with no Particulate Matter Sensor.
Specifications
Certificates and standards
IEC 61672: 1993
Class 2 Sound Level Meter
IEC 61252: 1993
Personal Sound Exposure Meter
CE Mark
Complies with 2014/53/EU Radio Equipment Directive and 2014/30/EU EMC Directive.
UKCA Mark
Complies with Radio Equipment Regulations 2017 and Electromagnetic Compatibility Regulations 2016.
Sound level measurement
LA
40dB to 120dB
LCPK
123dB
Overload detector flag
120.1dBA
Resolution
0.1dB
Frequency weighting
A, C, Z
Time weighting
Slow (1s), Fast (1/8s)
Sound exposure measurement
Readings
SPL, LEQ, LEX8h, LAVG, TWA, LMIN, LMAX, Dose (%), Projected Dose (%,8h)
Exchange Rate
3dB, 4dB, 5dB, 6dB
Criterion Level for 100% Dose
75 to 90dBA (in 5 dB Increments)
Criterion Threshold
None, 80db, 90dB
Simultaneous analysers
1
Ear defender SNR range
5dB to 45dB
Environmental measurement temperature range
-40˚C to +125˚C (limited by environmental range)
Temperature resolution
0.1˚C
Humidity
0% – 100% RH
Humidity resolution
1% RH
Motion
3 axis, 10s detection time
Sensors
Particulate Matter measurement (optional)
Mass concentration range
0 to 1000μg/m3
Measurement interval
1s, 1min, 5min, 15min
Mass concentration precision
0 to 100μg/m3 ±10 μg/m3
PM1, PM2.5
100 to 1000μg/m3 ±10% m.v.
Mass concentration precision
0 to 100μg/m3 ±25 μg/m3
PM4, PM10
100 to 1000μg/m3 ±25% m.v.
Sensor self-clean interval
8h, 96h
Gas Sensors
(Other sensors and spans available. Contact factory)
All Gas measurement (optional)
VOC-200
Measurement Range:
0-200 ppm
Resolution:
0.1 ppm
Maximum Overload:
1000 ppm
CO2 (Carbon Dioxide) measurement (optional)
CO2-5000
Measuring range
0 to 5000 ppm
Accuracy
± (50 ppm + 2.5% of reading)
@ 400 – 1,000 ppm
± (50 ppm+ 3% of reading)
@ 1,001 – 2,000 ppm
± (40 ppm+ 5% of reading)
@ 2,001 – 5,000 ppm
Repeatability
±10 ppm
Response
60s
Measurement interval
30s
Calibration
Automatic (in fresh air)
CO (Carbon Monoxide) measurement (optional)
CO-1000
Measurement Range:
0-1000ppm
Resolution:
0.1ppm
Maximum Overload:
2000ppm
HCHO / CH2O (Formaldehyde) measurement (optional)
HCHO-5
Measurement Range:
0-5ppm
Resolution:
0.01ppm
Maximum Overload:
100ppm
NO2 (Nitrogen Dioxide) measurement (optional)
NO2-100
Measurement Range:
0-100ppm
Resolution:
0.1ppm
Maximum Overload:
500ppm
O3 (Ozone) measurement (optional)
O3-5
Measurement Range:
0-5ppm
Resolution:
0.01ppm
Maximum Overload:
10ppm
H2S (Hydrogen Sulphide) measurement (optional)
H2S-100
Measurement Range:
0-100ppm
Resolution:
0.1ppm
Maximum Overload:
200ppm
AsH3 (Arsine) measurement (optional)
ASH3-1
Measurement Range:
0-1ppm
Resolution:
<0.02ppm
Maximum Overload:
20ppm
CH4S (Methyl Mercaptan) measurement (optional)
CH4S-10
Measurement Range:
0-10ppm
Resolution:
0.01ppm
Maximum Overload:
50ppm
Cl2 (Chlorine) measurement (optional)
CL2-5
Measurement Range:
0-5ppm
Resolution:
<0.01ppm
Maximum Overload:
10ppm
ClO2 (Chlorine Dioxide) measurement (optional)
CLO2-1
Measurement Range:
0-1ppm
Resolution:
0.01ppm
Maximum Overload:
5ppm
ETO (Ethylene Oxide) measurement (optional)
ETO-10
Measurement Range:
0-10ppm
Resolution:
0.01ppm
Maximum Overload:
50ppm
H2 (Hydrogen) measurement (optional)
H2-1000
Measurement Range:
0-1000ppm
Resolution:
0.1ppm
Maximum Overload:
2000ppm
NH3 (Ammonia) measurement (optional)
NH3-100
Measurement Range:
0-100ppm
Resolution:
0.1ppm
Maximum Overload:
200ppm
PH3 (Phosphine) measurement (optional)
PH3-20
Measurement Range:
0-20ppm
Resolution:
<0.01ppm
Maximum Overload:
50ppm
SO2 (Sulphur Dioxide) measurement (optional)
SO2-5
Measurement Range:
0-5ppm
Resolution:
<0.01ppm
Maximum Overload:
10ppm
CH4S (Methanethiol) measurement (optional)
CH4S-10
Measurement Range:
0-10ppm
Resolution:
0.01ppm
Maximum Overload:
50ppm
Connectivity
Bluetooth™ 5.0
USB
Data logging
Data logging
Internal eMMC memory
Summary results for the measurement time
File type
reports: *.txt;
history: *.csv
Log intervals
1s, 10s, 30s, 1m, 5m, 10m, 15m
Parameters
As selected in the REPORTS menu
Display
1.8” colour LCD, 128×160, always-on
Keypad
2 multifunction buttons
Optical
Multicolour ‘info LED’
Battery
Operating time (depends on features)
30 hours to 160 hours (PM sampling 1s to 15min)
Type
Li-Pol 3.7V / 3000mAh
Power consumption
110mA (typical)
Charging source
USB-C, 750mA
Wireless Qi – docking station
Charging time
<5 hours
Auto power-off
1 hour (no motion, not recording)
Calibration adapters
A calibration adaptor to interface the PED 1780 to a standard 0.5” sound/noise calibration standard is available (PED 1993)
A calibration adaptor for gas sensors is available (PED 2006)
Environmental
Operating temperature
0 ̊C to +50 ̊C
Operating humidity
0% – 95% RH, non-condensing
Storage temperature
-30 ̊C to +60 ̊C
Storage humidity
0% – 95% RH, non-condensing
Notes
All specification values are typical unless otherwise stated.
Continuous product development and innovation are the policy of our company. Therefore, we reserve the right to change the specifications without prior notice.
Industries served